Nanex™ multiSert+™
Nanex™ multiSert+™ | ||||
Model name | NY1-SP | NC1-SP | ||
---|---|---|---|---|
Optic design | Aspheric design with sharp optic edge | |||
Optic & haptic materials | Hydrophobic acrylic with UV and blue light filter |
Hydrophobic acrylic with UV-Filter |
||
Haptic design | Modified C-loop, 5° angulation | |||
Diameter (optic/OAL) |
6.0 mm/13.0 mm | |||
Power | 6.00 to +30.00 D (in 0.50 D increments) | |||
Nominal A-constant* |
119.2 | |||
Injector | multiSert+™ preloaded | |||
Front injector tip outer diameter |
1.62 mm | |||
Incision size | As low as 1.8 mm | |||
Optimized constants† | Haigis | a0 = -0.2676 | a1 = 0.2382 | a2 = 0.1993 |
Hoffer Q | pACD = 5.715 | |||
Holladay 1 | SF = 1.904 | |||
SRK/T | A = 119.112 |
*The A-constant is presented as a starting point for the lens power calculation. When calculating the exact lens power, it is recommended that calculations be performed individually, based on the equipment used and operating surgeon’s own experience.
†These optimized constants for the calculation of intraocular lens power published by IOLCon on their website: https://iolcon.org are calculated from 211 clinical results for Nanex™ multiSert+™ model NY1-SP/NC1-SP as of September 9, 2021. These constants are based on actual surgical data and are provided by IOLCon as a starting point for individual constant optimizations. The information available on the website is based on data originating from other users and not by HOYA Surgical Optics (“HSO”). HSO therefore does not warrant the correctness, completeness and currentness of the contents on the said website.
Information contained is intended for health care professionals. For a full list of indications and contra indications please refer to the Instructions For Use. Some of the products and/or specific features as well as the procedures featured in this document may not be approved in your country and thus may not be available there. Please contact our regional representative regarding individual availability in your country. HOYA, Nanex and multiSert+ are trademarks of the HOYA Corporation or its affiliates. ©2023 HOYA Medical Singapore Pte. Ltd. All rights reserved.
- Comparative porcine eye study: study result. David J Apple International Laboratory for Ocular Pathology, University Hospital Heidelberg. Report on file
Consistent control at your fingertips with Nanex™ multiSert+™
Wound protection
Minimizes wound stretch and allows for minimally invasive surgery through the smallest nozzle size available for an open-loop preloaded hydrophobic IOL system (outer diameter: 1.62 mm).1
Push and screw mode with ability to control insertion depth
Nanex™ multiSert+™ is a 4-in-1 delivery system that allows you to achieve outstanding delivery consistency with your choice of injection and insertion style.
- Comparative porcine eye study: study result. David J Apple International Laboratory for Ocular Pathology, University Hospital Heidelberg. Report on file.
*Third-party trademarks used herein are the property of their respective owners.
Protect your incision quality
Nanex™ multiSert+™ provides the smallest final incision size and least amount of wound stretch when performing cataract surgery through a 1.8 mm or 2.0 mm incision1
The following data is from a study comparing incision sizes in porcine eyes (n = 10, +20.0 D).
*The tests began with the condition that the plunger was pushed forward by 5 mm
†Third-party trademarks used herein are the property of their respective owners.
- Data on file, HOYA Medical Singapore Pte. Ltd, 2019.
Smooth IOL delivery
Nanex™ multiSert+™ is designed to provide a smooth lens delivery in comparison with other IOL delivery systems to mitigate risk of abrupt release1