Vivinex™ Toric
UNPRECEDENTED CLARITY AND ROTATIONAL STABILITY.
Designed for outstanding optical quality, Vivinex™ Toric has proven rotational stability for precise astigmatism correction and provides patients with an astigmatic cornea with unprecedented clarity of vision. Product quality, dedication and attention to detail are deeply rooted in our Japanese heritage, and with 1 million lenses sold worldwide, surgeons‘ trust in Vivinex™ is proven.
Vivinex™ Toric offers the following benefits:
- Glistening-free hydrophobic acrylic IOL material1,3
- Proprietary aspheric optic design for improved image quality2
- Active oxygen processing treatment and sharp optic edge to reduce PCO3
- Vivinex™ Toric IOL preloaded in the proven VivinexTM iSert® injector system
- Outstanding rotational stability, Median rotation 1.1° [ range: 0.0° – 5.0° ]4
- 100% of lenses (n=103) had 5° of rotation from their initial axis at end of surgery through all follow up visits at 1 hour, 1 week, 1 month and 6 months4
- 1 Glistening-free per Miyata scale; study result of the David J Apple International Laboratory for Ocular Pathology, University Hospital Heidelberg. Report on file.
- 2 Pérez-Merino P, Marcos S. Effect of intraocular lens decentration on image quality tested in a custom model eye. J Cataract Refract Surg. 2018;44(7):889–896.
- 3 Clinical Evaluation of the HOYA Vivinex™ IOL, HOYA data on file DoF-PHIV-101-SP2-24mIR-20082019 (2019).
- 4 Schartmüller D, Schriefl S, Schwarzenbacher L, Leydolt C, Menapace R. True rotational stability of a single-piece hydrophobic intraocular lens. Br J Ophthalmol. 2019; 103:186-190.
- Some of the products and/or specific features as well as the procedures featured in this document may not be approved in your country and thus may not be available there. Design and specifications are subject to change without prior notice as a result of ongoing technical development. Please contact our regional representative regarding individual availability in your country. HOYA, Vivinex and iSert are trademarks of the HOYA Corporation or its affiliates. ©2019 HOYA Medical Singapore Pte. Ltd. All rights reserved.
Specifications
Attribute
|
Value
|
Model names
|
XY1A
|
Optic material
|
Hydrophobic acrylic Vivinex™ with UV- and blue light filter
|
Optic design
|
Biconvex with sharp textured optic edge Anterior: Aspheric design Posterior: Toric design
|
Haptic design
|
Textured-rough haptic surface
|
Haptic material
|
Hydrophobic acrylic Vivinex™ with UV- and blue light filter
|
Diameter (optic/OAL)
|
6.00 mm / 13.00 mm
|
Power
|
+10.00 to +30.00 D (in 0.50 D increments)
|
Cylindrical Power
|
1.00 to 6.00 D (T2 to T9) T2 to T3 in 0.50 D increments T3 to T9 in 0.75 D increments
|
Front injector tip outer diameter
|
1.70 mm
|
Recommended incision size
|
2.20mm
|
Nominal A-constant
|
118.9
|
Optimized constants
|
Haigis a0 = -0.8394 a1 = 0.2023 a2 = 0.2272
Hoffer Q pACD = 5.7058
Holladay 1 sf = 1.9432
SRK/T A = 119.219
|
The A-constant is presented as a starting point for the lens power calculation. When calculating the exact lens power, it is recommended that calculations be performed individually, based on the equipment used and operating surgeon’s own experience.
Optimized Optical constants Source: https://iolcon.org Calculated from 910 clinical results based on caucasian patients for Vivinex™ Model XY1/XC1 as of August 22, 2019.
Model XY1A |
Cylinder Power
at IOL Plane
|
Cylinder Power
at Corneal Plane5
|
T2
|
1.00 D
|
0.69 D
|
T3
|
1.50 D
|
1.04 D
|
T4
|
2.25 D
|
1.56 D
|
T5
|
3.00 D
|
2.08 D
|
T6
|
3.75 D
|
2.60 D
|
T7
|
4.50 D
|
3.12 D
|
T8
|
5.25 D
|
3.64 D
|
T9
|
6.00 D
|
4.17 D
|
5Based on an average pseudophakic human eye.